Valiantsin DzerakhandClaude Opus 5.5 6433550e3d Scale the 1.2.1 gear rotation threshold by the AI update's frame delta, as 1.4.3 does (#330, #984)
ActorCheckRotateModule's update compared the angle a gear turned since the last update with one 30 Hz frame's worth,
so above 30 fps gears and water wheels read as stopped and the Riogok, Turakamik and Wind Temple doors stayed shut.
The new set gears keeps the update context's +8 (frames elapsed in 30 Hz units, the value 1.4.3 divides by) and
multiplies the threshold by it. Measured: the context is 0.25 at 120 fps with the real-time step and 0.5 at 60 fps
without it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>